UDC
681.518.5+656.25

NEW DEVICES FOR REGISTRATION OF PARAMETERS OF RAILWAY AUTOMATION HARDWARE WITHIN APK-DK (STDM) SYSTEM New devices for registration of parameters of railway automation hardware within APK-DK (STDM) system

Published in Transport automation research · Pages 282–297 · Rubric: Technical diagnostics and prediction
Received: 12.09.2015 Accepted: 15.09.2015 Published: 25.09.2015 Language of publication: RUS
The article describes the principles of building and technical solutions for ADSU- 24/16 automation, which provides the registration and collection of test data, measurements of the parameters of railway automation devices, as well as INS-10.1 controllers, which are used in the system of dispatching control of APK-DK (STDM), as devices for voltage, insulation resistance and the difference (shift angle) of phases measurements in track circuits and power circuits of railway automation devices. The article also shows the functionality of INS-10.1 controllers, provides the description of the hardware, structure diagram and the specifications . INS-10.1 devices are widely implemented, including for replacement of PIK-10 controllers.
test automation, data hub, amplitude shift keying, modular principle, cyclic code, phase shift, galvanic isolation, measurement of voltage, insulation resistance, phase difference